Inspection Dashboard
AA
This Month
18
inspections completed
Revenue (Apr)
$8,420
+22% vs March
Avg Report Time
3.2h
-18 min vs avg
Client Rating
4.9
42 reviews
Recent Inspections
View All 42
INS-2026-0419
In Progress
2847 Lyndale Ave S, Uptown
Single Family -- 4bd/3ba -- 2,480 sqft -- Built 1924 -- $425,000
📅 Apr 19, 9:00 AM
⏱ ~3.5 hrs
📷 142 photos
Buyer Agent:
Sarah Kim, RE/MAX Results
Buyer:
Marcus Chen
INS-2026-0418
Draft
1204 W Lake St, Lowry Hill
Single Family -- 5bd/4ba -- 4,100 sqft -- Built 1912 -- $675,000
📅 Apr 18, 10:00 AM
📷 218 photos
📄 85% complete
Buyer:
Anika Kapoor
INS-2026-0417
Delivered
3648 Bryant Ave S, ECCO
Single Family -- 3bd/2ba -- 1,960 sqft -- Built 1948 -- $365,000
📅 Apr 17
📷 168 photos
✅ Delivered Apr 17 6PM
Buyer:
Jamie Rodriguez
INS-2026-0420A
Scheduled
820 Summit Ave, Kenwood
Single Family -- 4bd/3ba -- 3,800 sqft -- Built 1908 -- $750,000
📅 Apr 20, 9:00 AM
⏱ Est. 4 hrs
Buyer:
Jordan Park
INS-2026-0420B
Scheduled
2104 Dupont Ave S, Whittier
Single Family -- 4bd/2.5ba -- 2,680 sqft -- Built 1936 -- $449,000
📅 Apr 20, 2:00 PM
⏱ Est. 3 hrs
Buyer:
Lisa Nguyen
INS-2026-0415
Reviewed
3421 Harriet Ave, Kingfield
Single Family -- 3bd/2ba -- 1,840 sqft -- Built 1952 -- $389,000
📅 Apr 15
📷 156 photos
★ 5.0 review
Buyer:
Rachel Wong
Report: 2847 Lyndale Ave S
Edit Report
4
Safety Issues
12
Defects
8
Monitor Items
18
Informational
Key Findings
View Full Report
Safety
4
Safety
Electrical Panel
Double-tapped breaker on 20A circuit
Two wires connected to a single breaker terminal in the main panel. Fire hazard. Recommend licensed electrician repair immediately.
📷1
📷2
Safety
Water Heater
Missing TPR valve discharge pipe
Temperature/pressure relief valve has no discharge pipe routed to within 6" of floor. Scald hazard. Immediate correction recommended.
📷1
Major Defects
3 of 12
Defect
Basement NW Corner
Evidence of moisture intrusion
Efflorescence and staining on foundation wall. Moisture meter reading 28% (normal <15%). Recommend waterproofing evaluation by specialist.
📷1
📷2
📷3
Defect
Roof
Aging shingles with curling at ridge
Asphalt shingles approximately 18-20 years old. Curling and granule loss observed at ridge and south exposure. 3-5 years remaining life estimated.
📷1
📷2
Monitor
2 of 8
Monitor
HVAC
Furnace age — approaching end of life
Carrier forced-air furnace, installed 2008. Unit is 18 years old (avg life 15-20 years). Functioning at time of inspection. Budget for replacement within 2-3 years.
Revenue -- April 2026
Inspections completed
18
Standard inspection
$450 avg
Radon test add-on
$150 x 12
Sewer scope add-on
$225 x 8
Total revenue
$8,420
Outstanding invoices
$1,350
Report Templates
+ New
📄
Standard Single Family
12 sections -- 240 items
used 34x
📄
Townhouse / Condo
10 sections -- 180 items
used 6x
📄
Multi-Family (2-4 unit)
14 sections -- 320 items
used 2x
📄
New Construction
8 sections -- 160 items
used 0x
📄
Radon Only
1 section -- 12 items
used 12x
📄
Sewer Scope Only
1 section -- 8 items
used 8x